Define LQI sensors as "signal_strength" device class
This commit is contained in:
@@ -19,7 +19,7 @@ sensor:
|
||||
name: "Bathroom switch LQI"
|
||||
state_topic: "z2m_deconz/bathroom_switch"
|
||||
availability_topic: "z2m_deconz/bridge/state"
|
||||
icon: "mdi:signal"
|
||||
device_class: "signal_strength"
|
||||
unit_of_measurement: "lqi"
|
||||
value_template: "{{ value_json.linkquality }}"
|
||||
|
||||
|
||||
@@ -15,7 +15,7 @@ sensor:
|
||||
name: "Bed LED LQI"
|
||||
state_topic: "z2m_deconz/bed_led"
|
||||
availability_topic: "z2m_deconz/bridge/state"
|
||||
icon: "mdi:signal"
|
||||
device_class: "signal_strength"
|
||||
unit_of_measurement: "lqi"
|
||||
value_template: "{{ value_json.linkquality }}"
|
||||
|
||||
|
||||
@@ -16,8 +16,8 @@ sensor:
|
||||
name: "Bedroom Opple LQI"
|
||||
state_topic: "z2m_deconz/opple_1"
|
||||
availability_topic: "z2m_deconz/bridge/state"
|
||||
icon: "mdi:signal"
|
||||
unit_of_measurement: "lqi"
|
||||
device_class: "signal_strength"
|
||||
value_template: "{{ value_json.linkquality }}"
|
||||
|
||||
automation:
|
||||
|
||||
@@ -10,8 +10,8 @@ sensor:
|
||||
name: "Bedside switch LQI"
|
||||
state_topic: "z2m_deconz/bedside_switch"
|
||||
availability_topic: "z2m_deconz/bridge/state"
|
||||
icon: "mdi:signal"
|
||||
unit_of_measurement: "lqi"
|
||||
device_class: "signal_strength"
|
||||
value_template: "{{ value_json.linkquality }}"
|
||||
|
||||
automation:
|
||||
|
||||
@@ -10,8 +10,8 @@ sensor:
|
||||
name: "Bedroom wall switch LQI"
|
||||
state_topic: "z2m_deconz/bedroom_wall_switch"
|
||||
availability_topic: "z2m_deconz/bridge/state"
|
||||
icon: "mdi:signal"
|
||||
unit_of_measurement: "lqi"
|
||||
device_class: "signal_strength"
|
||||
value_template: "{{ value_json.linkquality }}"
|
||||
|
||||
|
||||
|
||||
@@ -10,8 +10,8 @@ sensor:
|
||||
name: "Desk switch LQI"
|
||||
state_topic: "z2m_deconz/desk_switch"
|
||||
availability_topic: "z2m_deconz/bridge/state"
|
||||
icon: "mdi:signal"
|
||||
unit_of_measurement: "lqi"
|
||||
device_class: "signal_strength"
|
||||
value_template: "{{ value_json.linkquality }}"
|
||||
|
||||
|
||||
|
||||
@@ -16,8 +16,8 @@ sensor:
|
||||
name: "Living room Opple LQI"
|
||||
state_topic: "z2m_deconz/opple_2"
|
||||
availability_topic: "z2m_deconz/bridge/state"
|
||||
icon: "mdi:signal"
|
||||
unit_of_measurement: "lqi"
|
||||
device_class: "signal_strength"
|
||||
value_template: "{{ value_json.linkquality }}"
|
||||
|
||||
automation:
|
||||
|
||||
@@ -15,8 +15,8 @@ sensor:
|
||||
name: "Trust remote LQI"
|
||||
state_topic: "z2m_deconz/trust_remote"
|
||||
availability_topic: "z2m_deconz/bridge/state"
|
||||
icon: "mdi:signal"
|
||||
unit_of_measurement: "lqi"
|
||||
device_class: "signal_strength"
|
||||
value_template: "{{ value_json.linkquality }}"
|
||||
|
||||
automation:
|
||||
|
||||