This will enable or disable the sound effects when you press or touch the sensing area
This will enable or disable the vibration effects when you press or touch the sensing area
This will enable or disable control by sliding the button area
To configure which report will be sent when pressing the buttons
To configure which color will be displayed when the button is pressed. Value 1: (msb) Red. Value 2: Green. Value 3: Blue. Value 4: Reserved
Get the LED Strip color value Value 1: (msb) Red. Value 2: Green. Value 3: Blue. Value 4: buzzer and vibrator. (1=ON, 0=OFF)
Set the low battery value. Range: 10% - 50%.
Reset to factory defaults
Off: No heating, only frost protection. Heat: Room temperature will be kept at the configured setpoint. Heat Eco: Energy save heating mode. Room temperature will be lowered to the configured eco setpoint in order to save energy. Full Power: Full power heating. This mode is left automatically after 5 minutes. Manufacturer Specific: Direct valve control mode. The valve opening percentage can be controlled using the switch multilevel command class.
Allows rotating the LCD contents by 180 degrees. Default: Normal
0: No Timeout, LCD always on. 5-30: Timeout after 5-30s. Default: 0 (LCD always on)
Default: Backlight enabled
Default: Send once a day
0: Don't send temperature automatically. 1-50: Report temperature at 0.1-5.0°C temperature difference. Default: 5 (Delta = 0.5°C)
0: Don't send Valve opening percentage automatically. 1-100: Report valve opening percentage at a delta of 1-100%. Default: 0
Default: Medium sensibility
206-255: -5.0 to -0.1°C. 0-50: 0°C-5°C. 128: External Temperature Sensor. Default: 0 (0.0°C Offset)
This parameter is configured the delay time before PIR sensor can be triggered again to reset motion timeout counter. Value = 0 will disable PIR sensor from triggering until motion timeout has finished.
This configures the clear time when your motion sensor times out and sends a no motion status.
This parameter is configured the sensitivity that motion detect. 0 - PIR sensor disabled. 1 - Lowest sensitivity. 11 - Highest sensitivity.
Enable/disable sensor binary report when motion event is detected or cleared
This parameter is configured the enabled or disabled send BASIC_SET command to nodes that associated in group 2 and group 3.
Define Basic Set Value when motion event is triggered and / or cleared
This parameter is configured the threshold value that alarm level for temperature. When the current ambient temperature value is larger than this configuration value, device will send a BASIC_SET = 0xFF to nodes associated in group 3. If current temperature value is less than this value, device will send a BASIC_SET = 0x00 to nodes associated in group 3. Value = [Value] x 0.1(Celsius / Fahrenheit) Available Settings: -400 to 850 (40.0 to 85.0 Celsius) or -400 to 1185 (-40.0 to 118.5 Fahrenheit). Default value: 239 (23.9 Celsius) or 750 (75.0 Fahrenheit)
Enable or Disable LED over TriSensor This completely disables all LED reaction regardless of Parameter 9 - 13 settings
This setting changes the color of the LED when your TriSensor sends a motion report.
This setting changes the color of the LED when your TriSensor sends a temperature report.
This setting changes the color of the LED when your TriSensor sends a light report.
It is possible to change the color of what the LED blinks when your TriSensor sends a battery report.
This setting changes the color of the LED when your TriSensor sends a wakeup report.
Configure temperature sensor scale type, Temperature to report in Celsius or Fahrenheit
Change threshold value for change in temperature to induce an automatic report for temperature sensor. Scale is identical setting in Parameter No.20. 0-> Disable Threshold Report for Temperature Sensor. Setting of value 20 can be a change of -2.0 or +2.0 (C or F depending on Parameter No.20) to induce automatic report or setting a value of 2 will be a change of 0.2(C or F). Available Settings: 0 to 250.
Change threshold value for change in lux to induce an automatic report for light sensor.
This parameter is configured the time interval for temperature sensor report. This value is larger, the battery life is longer. And the temperature value changed is not obvious.
This parameter is configured the time interval for light sensor report. This value is larger, the battery life is longer. And the light intensity changed is not obvious.
The current measuring temperature value can be add and minus a value by this setting. The scale can be decided by Parameter Number 20. Temperature Offset Value = [Value] * 0.1(Celsius / Fahrenheit) Available Settings: -200 to 200.
The current measuring light intensity value can be add and minus a value by this setting. Available Settings: -1000 to 1000.
This configuration defines the calibrated scale for ambient light intensity. Because the method and position that the sensor mounted and the cover of sensor will bring measurement error, user can get more real light intensity by this parameter setting. User should run the steps as blows for calibrating 1) Set this parameter value to default (Assumes the sensor has been added in a Z- Wave Network). 2) Place a digital light meter close to sensor and keep the same direction, monitor the light intensity value (Vm) which report to controller and record it. The same time user should record the value (Vs) of light meter. 3) The scale calibration formula: k = Vm / Vs. 4) The value of k is then multiplied by 1024 and rounded to the nearest whole number. 5) Set the value getting in 5) to this parameter, calibrate finished. For example, Vm = 300, Vs = 2600, then k = 2600 / 300 = 8.6667 k = 8.6667 * 1024 = 8874.7 => 8875. The parameter should be set to 8875.
Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor
Duration that the motion sensor must observe no motion before it will return to the no-motion state. If value greater than 255, effective value is rounded up to the nearest minute (255 -> 255 seconds, 256 -> 300 seconds)
Enable Motion Sensor, (1 minimum, 5 maximum sensitivity level)
Which commands to send when PIR motion sensor triggered OZW Ideal Value is Binary Sensor Report
Set the timeout of awake after the Wake Up CC is sent out. Available rang: 8 to 255 seconds.
Report the current power mode and the product state for battery power mode
Configure low battery value Value=10 to 50.
Enable/disable the selective reporting only when measurements reach a certain threshold or percentage set in the threshold settings. This is used to reduce network traffic.
Threshold change in temperature to induce an automatic report. Note: 1. The unit is Fahrenheit for US version, Celsius for EU/AU version. 2. The value contains one decimal point. E.g. if the value is set to 20, the threshold value = 2.0 C (EU/AU) or 2.0 F (US). When the temperature has changed by 2.0 (of the appropriate unit), a temperature report will be sent.
Threshold change in humidity to induce an automatic report. Note: 1. The unit is %. 2. The default value is 10, which means that a 10% change in humidity will trigger a report.
Threshold change in luminance to induce an automatic report.
Threshold change in battery level to induce an automatic report. Note: 1. The unit is %. 2. The default value is 10, which means that a 10% change in battery will trigger a report.
Threshold change in ultraviolet to induce an automatic report.
Enable/disable to send the alarm report of low temperature(Less than 15 Degress C)
Enable/disable to send a report when the measurement is more than the upper limit value or less than the lower limit value. Bit mask = 0, disable. Bit mask = 1, enable. Bit 0 = temperature. Bit 1 = humidity. Bit 2 = luminance. Bit 3 = ultraviolet. The above bit masks are used to enable/disable to send out a report when the measurement is less than the lower limit value. The below bit masks are used to enable/disable to send out a report when the measurement is more than the upper limit value. Bit 4 = temperature. Bit 5 = humidity. Bit 6 = luminance. Bit 7 = ultraviolet. Note: If USB power, the Sensor will check the limit every 10 seconds. If battery power, the Sensor will check the limit when it is waken up.
When the measurement is more than this upper limit, which will trigger to sent out a sensor report. High byte is the upper limit value. Low byte is the unit (0x01=Celsius, 0x02=Fahrenheit). 1. When unit is Celsius. Upper limit range: -40.0 to 100.0 C (0xFE70 to 0x03E8). E.g. The default upper limit of EU/AU version is 28.0 C (0x0118), when the measurement is more than 28.0C, it will be triggered to send out a temperature sensor report. 2. When unit is Fahrenheit. Upper limit range: -40.0 to 212.0 F (0xFE70 to 0x0848). E.g. The default upper limit of US version is 82.4F (0X0338), when the measurement is more than 82.4F, it will be triggered to send out a temperature sensor report.
When the measurement is less than this lower limit, which will trigger to sent out a sensor report. High byte is the lower limit value. Low byte is the unit (0x01=Celsius, 0x02=Fahrenheit). 1. When unit is Celsius. Lower limit range: -40.0 to 100.0 C (0xFE70 to 0x03E8). E.g. The default lower limit of EU/AU version is 0 C (0x0000), when the measurement is less than 0C, it will be triggered to send out a temperature sensor report. 2. When unit is Fahrenheit. Upper limit range: -40.0 to 212.0 F (0xFE70 to 0x0848). E.g. The default lower limit of US version is 32.0F (0x0140), when the measurement is less than 32.0F, it will be triggered to send out a temperature sensor report.
When the measurement is more than this upper limit, which will trigger to sent out a sensor report. Upper limit range: 0 to 100%. E.g. The default upper limit is 60%, when the measurement is more than 60%, it will be triggered to send out a humidity sensor report.
When the measurement is less than this lower limit, which will trigger to sent out a sensor report. Lower limit range: 0 to 100%. E.g. The default lower limit is 50%, when the measurement is less than 50%, it will be triggered to send out a humidity sensor report.
When the measurement is more than this upper limit, which will trigger to sent out a sensor report. Upper limit range: 0 to 30000 Lux. E.g. The default upper limit is 1000Lux, when the measurement is more than 1000Lux, it will be triggered to send out a Lighting sensor report.
When the measurement is less than this lower limit, which will trigger to sent out a sensor report. Lower limit range: 0 to 30000 Lux. E.g. The default lower limit is 100Lux, when the measurement is less than 100Lux, it will be triggered to send out a Lighting sensor report.
When the measurement is more than this upper limit, which will trigger to sent out a sensor report. Upper limit range: 1 to 11. E.g. The default upper limit is 8, when the measurement is more than 8, it will be triggered to send out a ultraviolet sensor report.
When the measurement is less than this upper limit, which will trigger to sent out a sensor report. Lower limit range: 1 to 11. E.g. The default lower limit is 4, when the measurement is less than 8, it will be triggered to send out a ultraviolet sensor report.
Note: 1. When the current measurement lower or equal (Upper limit - Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. After that, the upper limit report would be disabled again until the measurement lower or equal (Upper limit - Recover limit). 2. When the current measurement greater or equal (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. After that, the lower limit report would be disabled again until the measurement greater or equal (Lower limit + Recover limit). 3. High byte is the recover limit value. Low byte is the unit (0x01=Celsius, 0x02=Fahrenheit). 4. Recover limit range: 1.0 to 25.5 C/ F (0x0101 to 0xFF01 or 0x0102 to 0xFF02). E.g. The default recover limit value is 2.0 C/F (0x1401/0x1402), when the measurement is less than (Upper limit - 2), the upper limit report would be enabled one time or when the measurement is more than (Lower limit + 2), the lower limit report would be enabled one time.
Note: 1. When the current measurement lower or equal (Upper limit - Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. After that the upper limit report would be disabled again until the measurement lower or equal (Upper limit - Recover limit). 2. When the current measurement greater or equal (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. After that the lower limit report would be disabled again until the measurement greater or equal(Lower limit + Recover limit). 3. Recover limit range: 1 to 50% (0x01 to 0x32). E.g. The default recover limit value is 5%, when the measurement is less than (Upper limit - 5), the upper limit report would be enabled one time or when the measurement is more than (Lower limit + 5), the lower limit report would be enabled one time.
Note: 1. When the current measurement lower or equal (Upper limit - Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. After that the upper limit report would be disabled again until the measurement lower or equal (Upper limit - Recover limit). 2. When the current measurement greater or equal (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. After that the lower limit report would be disabled again until the measurement greater or equal (Lower limit + Recover limit). 3. Unit = 10*Recover limit (Lux) 4. Recover limit range: 10 to 2550Lux (0x01 to 0xFF). E.g. The default recover limit value is 100 Lux, when the measurement is less than (Upper limit - 100), the upper limit report would be enabled one time or when the measurement is more than (Lower limit + 100), the lower limit report would be enabled one time.
Note: 1. When the current measurement lower or equal (Upper limit - Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. After that the upper limit report would be disabled again until the measurement lower or equal (Upper limit - Recover limit). 2. When the current measurement greater or equal (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. After that the lower limit report would be disabled again until the measurement greater or equal(Lower limit + Recover limit). 3. Recover limit range: 1 to 50% (0x01 to 0x32). E.g. The default recover limit value is 5%, when the measurement is less than (Upper limit - 5), the upper limit report would be enabled one time or when the measurement is more than (Lower limit + 5), the lower limit report would be enabled one time.
Get the out-of-limit state of the Sensors. Bit mask = 0, within the limit. Bit mask = 1, out of the limit. Bit 0 = temperature. Bit 1 = humidity. Bit 2 = luminance. Bit 3 = ultraviolet. The above bit masks are used to indicate whether the current measurements of the Sensors are out of the lower limit. The below bit masks are used to indicate whether the current measurements of the Sensors are out of the upper limit. Bit 4 = temperature. Bit 5 = humidity. Bit 6 = luminance. Bit 7 = ultraviolet.
Default value: Celsius for EU/AU version, Fahrenheit for US version.
Enable/disable the LED blinking for motion, wakeup, and sensor report.
Reset The Reporting Group Configuration (101 to 103) to default
Which reports need to send automatically in timing intervals for group 1. Bitmask: 10000000 - 128 - Luminance 01000000 - 64 - Humidity 00100000 - 32 - Temperature 00010000 - 16 - Ultraviolet 00000001 - 1 - Battery 10100000 - 160 - Luminance and Temperature (32+128) 11110001 - 241 - All (1+16+32+64+128)
Which reports need to send automatically in timing intervals for group 2. Bitmask: 10000000 - 128 - Luminance 01000000 - 64 - Humidity 00100000 - 32 - Temperature 00010000 - 16 - Ultraviolet 00000001 - 1 - Battery 10100000 - 160 - Luminance and Temperature (32+128) 11110001 - 241 - All (1+16+32+64+128)
Which reports need to send automatically in timing intervals for group 3. Bitmask: 10000000 - 128 - Luminance 01000000 - 64 - Humidity 00100000 - 32 - Temperature 00010000 - 16 - Ultraviolet 00000001 - 1 - Battery 10100000 - 160 - Luminance and Temperature (32+128) 11110001 - 241 - All (1+16+32+64+128)
Reset The Reporting Group Interval Configuration (111 to 113) to default
The interval for sending reports for group 1. The effective behavior of this setting depends on the device's power source: - If the device is on USB power, it will send the reports at the configured interval; set it to something low (~15-60 seconds) to get frequent updates from a powered device. - If the device is on battery, the sensor will never report in more often than its configured wake interval, regardless of what this setting is configured to; setting this to 3601 when the wake interval is 3600 would make this group report in every 7200 seconds. 240 seconds is the minimum wake interval, but will quickly use battery.
The interval for sending reports for group 2. The effective behavior of this setting depends on the device's power source: - If the device is on USB power, it will send the reports at the configured interval; set it to something low (~15-60 seconds) to get frequent updates from a powered device. - If the device is on battery, the sensor will never report in more often than its configured wake interval, regardless of what this setting is configured to; setting this to 3601 when the wake interval is 3600 would make this group report in every 7200 seconds. 240 seconds is the minimum wake interval, but will quickly use battery.
The interval for sending reports for group 3. The effective behavior of this setting depends on the device's power source: - If the device is on USB power, it will send the reports at the configured interval; set it to something low (~15-60 seconds) to get frequent updates from a powered device. - If the device is on battery, the sensor will never report in more often than its configured wake interval, regardless of what this setting is configured to; setting this to 3601 when the wake interval is 3600 would make this group report in every 7200 seconds. 240 seconds is the minimum wake interval, but will quickly use battery.
Temperature calibration (the available value range is [-128,127] or [-12.8C,12.7C]). Note: 1. High byte is the calibration value. Low byte is the unit (0x01=Celsius,0x02=Fahrenheit) 2. The calibration value (high byte) contains one decimal point. E.g. if the value is set to 20 (0x1401), the calibration value is 2.0C (EU/AU version) or if the value is set to 20 (0x1402), the calibration value is 2.0F (US version) 3. The calibration value (high byte) = standard value - measure value. E.g. If measure value =25.3C and the standard value = 23.2C, so the calibration value= 23.2C - 25.3C= -2.1C (0xEB). If the measure value =30.1C and the standard value = 33.2C, so the calibration value= 33.2C - 30.1C=3.1C (0x1F). Default value: 1 for EU/AU version, 2 for US version.
The calibration value = standard value - measure value. (the available value range is [-50, 50]). If measure value =80RH and the standard value = 75RH, so the calibration value= 75RH-80RH = -5RH (0xFB). If the measure value =85RH and the standard value = 90RH, so the calibration value= 90RH-85RH = 5RH (0x05).
The calibration value = standard value - measure value. (the available value range is [-1000, 1000]). If measure value =800Lux and the standard value = 750Lux, so the calibration value= 750-800 = -50 (0xFFCE). If the measure value =850Lux and the standard value = 900Lux, so the calibration value= 900-850 = 50 (0x0032).
The calibration value = standard value measure value. (the available value range is [-10, 10]). If measure value =9 and the standard value = 8, so the calibration value= 8-9 = -1 (0xFE). If the measure value =7 and the standard value = 9, so the calibration value= 9-7 = 2 (0x02).
Enable/disable Lock Configuration
Reset to factory defaults